Your Position:Home>News>Technical Information>General Conditions for Splicing Steel Cable Belts

General Conditions for Splicing Steel Cable Belts

Time:2021-03-20 Click:1213

1.Work place
In order to ensure quality and durability of a splice, a clean and sheltered work place as well as correct use and application of the splicing products are essential.
The exposed surfaces of stripped cables,bevel cuts and cover pads must be kept absolutely clean.
2.Conveyor belt
Only clean and dry conveyor belts can be spliced reliably.Dirty or contaminated belts must be cleaned.
Water-soluble contaminations should be scraped off and then washed away with water and dried.
Oil and grease should be removed with Cleaning fluid.
3.Equipment and tools
Tools and equipment must be in perfect working order.Measuring instruments have to be calibrated.
4.Splicing products
TOPTECH Splicing products are suitable for cable belts with grade M and N rubber covers.
Splicing products have to be stored in a dry and dark place at a temperature of max.25℃(77℉)in accordance with DIN7716.
Check expiration dates and dispose of outdated and contaminated products.
5.Ambient conditions
Any influence of humidity,e.g.formation of condensation water(temperature falling below dew point)must be absolutely avoided.
Precondition products to ambient temperature if necessary.
Erect a splicing shelter/tent for protection against sun,dust,wind,rain etc.
6.Documentation
During the splicing operation all irregularities and special conditions have to be recorded.
The record sheet must be signed by the supervisor at the end of each shift.
7.Precautions
Observe safety precautions on the cans.
Note:
Our recommendations result from field tests and years of experience.However,in view of the different materials and work conditions beyond our control,we recommend to make corresponding tests locally in any case.We cannot assume any kond of liability resulting from these recommendations.

广州市迪普特工业技术有限公司 | 服务热线:400-881-7822 |  粤ICP备16105105号